Sputtr.com | Alternative Search Engine

Backfilled

Design and construction of the backfilled pit cover system at ...

Design and construction of the backfilled pit cover system at Whistle Mine, Canada: a case study Brian Ayres 1, Lisa Lanteigne 2 and Mike O'Kane 3 1 O'Kane Consultants Inc., 134 - 335 Packham Ave., Saskatoon, SK, S7N 4S1, Canada 2 Inco Limited, Copper Cliff, ON, P0M 1N0, Canada 3 O'Kane ...

Long-term Stability of a Backfilled Room-and-Pillar Test ...

Long-term Stability of a Backfilled Room-and-Pillar Test Section at the Buick Mine, Missouri, USA

LATERAL PRESSURES BEHIND RETAINING WALLS BACKFILLED WITH TIRE ...

LATERAL PRESSURES BEHIND RETAINING WALLS BACKFILLED WITH TIRE DERIVED AGGREGATE Tire derived aggregate (TDA) consists of scrap tires cut into pieces typically ranging in size from 0.5 in. (12 mm) and 12 in. (305 mm) and has been used as a construction material in several states over 20 years for ...

Stability Analysis of a Backfilled Room-and-Pillar Mine

UNITED STATES BUREAU OF MINES UNITED STATES DEPARTMENT OF THE INTERIOR REPORT OF INVESTIGATIONS/1995 RI 9565 Stability Analysis of a Backfilled Room-and-Pillar Mine By D. R. Tesarik, J. B. Seymour, T. R. Yanske, and R. W. McKibbin

DMRB VOLUME 2 SECTION 1 PART 5 - BD 30/87 - BACKFILLED ...

Backfilled Retaining Walls and Bridge Abutments Summary: This Departmental Standard sets out the design and construction requirements for backfilled walls and bridge abutments.

Borehole and Monitoring Well Destruction

If necessary the well shall be cleaned so that undesirable materials are removed. 5.3 Small Diameter, Shallow Soil Boring Abandonment Small diameter (less than 4-inch diameter) soil borings completed to a depth less than 20 feet, without encountering groundwater can be backfilled with bentonite chips ...

EXCAVATION, TRENCHING AND BACKFILLING

Whenever wet or otherwise unstable soil that is incapable of properly supporting the structure or pipe, as determined by the Engineer, is encountered in the bottom of the trench, such soil shall be removed to the depth shown on the plans or determined by the Engineer and the trench backfilled to the ...

CONSTRUCTION STANDARDS SECTION CS 3 TRENCH FOUNDATION ...

The conduit shall be placed in the bottom of the trench and the trench shall be backfilled with slurry cement backfill containing not less than 282 lbs. of Portland cement per cubic yard. B. Slurry cement backfill shall be backfilled to within 1-1/2 inches of the finish grade, and then topped with ...

EVALUATION OF THE EARTH PRESSURES IN BACKFILLED STOPES USING ...

57 ième CONGRÈS CANADIEN DE GÉOTECHNIQUE 57 TH CANADIAN GEOTECHNICAL CONFERENCE 5 ième CONGRÈS CONJOINT SCG/AIH-CNN 5 TH JOINT CGS/IAH-CNC CONFERENCE EVALUATION OF THE EARTH PRESSURES IN BACKFILLED STOPES USING LIMIT EQUILIBRIUM ANALYSIS Michael James, École Polytechnique, Canada Li Li ...

TWO-DIMENSIONAL SIMULATION OF PYRITE OXIDATION AND POLLUTANT ...

1 TWO-DIMENSIONAL SIMULATION OF PYRITE OXIDATION AND POLLUTANT TRANSPORT IN BACKFILLED OPEN CUT COAL MINES F. DOULATI ARDEJANI Assistant Professor, Faculty of Mining and Geophysics, Shahrood University of Technology, Shahrood, Iran R. N. SINGH Professor of Mining Engineering, Faculty of ...