Sputtr.com | Alternative Search Engine

Calibrator

Loop Calibrator Model 334A

Loop Calibrator Model 334A •All milliamp loop functions Source milliamps Simulate two-wire transmitters Read milliamp outputs Power & measure two-wire transmitters Read DC Volts to check power supplies •Compact and lightweight Easy to carry - less than a pound Includes padded nylon carrying ...

MILLIAMP LOOP CALIBRATOR MODEL 334

SOURCE MILLIAMPS 1) Disconnect one or both input wires from the device to be cali-brated 2) Connect the red lead of the calibrator to the plus (+) input of the device and the black lead to the minus (-) 3) Move the power switch to mA or % Output current is continuously adjustable with the "QUIK ...

Pneumatic Calibrator PneuCal IV-B

Pneumatic Calibrator PneuCal IV-B •Tough enough for your truck Mounted in a weatherproof case •Calibrate pneumatic instruments Pneumatic controllers, pressure gauges and pneumatic recorders •Check P/P instruments Accurately control two pressures •Test pressure switches Indicates open and ...

kE NDALL GENIUS™ Checker / Calibrator

3 GENIUS ™ 2 Checker / Calibrator Operation and Service Manual Section III - Icon Identification SN Serial Number Corrugated Recycles STERILE Keep Away From Sunlight Keep Dry Single Use LOT FRAGILE THIS SIDE UP DEHP - FREE 0° 40° Avoid Temperature Extremes Do not use if package is opened or ...

A how to on Loop Calibration and Maintenance

The following example will utilize a 250 Ωto take advantage of the 0-100% and 25% buttons on the Fluke 707 (25% or 4 mA = 1 V). 4 Fluke Corporation Troubleshooting and Maintenance Using Fluke Loop Calibrators Figure 4 Resistor Sourced Generated Fluke Loop Value Application Current Value Voltage Calibrator ...

1875 Smart Calibrator Instruction Manual

1 INTRODUCTION This manual covers operation of the Mettler-Toledo Thornton, Inc. 1875 Smart Calibrator for calibrating, verifying and printing out certificates for the 770MAX Multiparameter Analyzer/Transmitter measuring circuits.

Title: Dose Calibrator Tests

University of Texas Southwester Medical Center Title: Procedure No. 11 Date: May 29, 1996 At Dallas Radiation Safety Dose Calibrator Tests Latest Revision: June 8, 2009 Page 1 of 3 I. Purpose This procedure will discuss the tests that need to be performed on dose calibrators used for ...

Pressure Calibrator CheckMate™ 600

Safety considerations It is imperative that all system pressure is re lieved prior to making any connections or dis con nec tions. Failure to relieve system pressure could result in serious personal injury and/or equipment damage.

METER CALIBRATOR MODEL MC-10 Revision C

METER CALIBRATOR MODEL MC-10 Revision C OPERATING MANUAL 734A1037 Revision C General Component Design, Inc. Electronic Design & Manufacture Minneapolis, MN.

Ultima®/Ultima® X Series Controller and Calibrator

Ultima ® /Ultima ® X Series Controller and Calibrator instruction manual"! WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR USING OR SERVICING THESE PRODUCTS.