Sputtr.com | Alternative Search Engine

Comis

COMIS — An International Multizone Air-Flow and Contaminant ...

LBNL-42182 This report was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology, of the U.S. Department of Energy under Contract No. DE-AC03-76F00098.-1-COMIS — An International Multizone Air-Flow and Contaminant Transport Model Helmut ...

Multizone Air Flow Modelling (COMIS)

Energy Conservation in Buildings and Community Systems Multizone Air Flow Modelling (COMIS) Summary of IEA Annex 23 Multizone Airflow Modelling (COMIS) Within the Energy Conservation in Buildings and Community Systems Programme (Duration 1992-1996) Peter Warren

LINKING THE COMIS MULTI-ZONE AIRFLOW MODEL WITH THE ...

1 LINKING THE COMIS MULTI-ZONE AIRFLOW MODEL WITH THE ENERGYPLUS BUILDING ENERGY SIMULATION PROGRAM Joe Huang, Fred Winkelmann, and Fred Buhl, Lawrence Berkeley National Laboratory, Berkeley CA, USA Curtis Pedersen, Daniel Fisher, Richard Liesen, Russell Taylor, and Richard Strand, The Building ...

The California Community College Chancellor’s Office ...

The data files submitted cover the following areas: • Student Characteristics • Student Course Activity and Outcomes • Course Inventory • Staff Inventory • Staff Workload • VTEA, DSPS, SF, EOPS, Calendar Process Components of COMIS • Syntactical and referential edits • Detailed Edit and Load ...

TRNFLOW: Integration of COMIS into TRNSYS TYPE 56

TRNFLOW: Integration of COMIS into TRNSYS TYPE 56 Andreas Weber 1, Markus Koschenz 1, Stefan Holst 2, Marion Hiller 2 1 EMPA, Abteilung Energiesysteme/Haustechnik, CH-8600 Dübendorf

TRNFLOW: Integration of the airflow model COMIS into the ...

TRNFLOW TRANSSOLAR Energietechnik GmbH 1 TRNFLOW: Integration of the airflow model COMIS into the multizone building model of TRNSYS M. Hiller 1, S. Holst 1, T. Welfonder 1, A. Weber 2, M. Koschenz 2 TRANSSOLAR Energietechnik GmbH 1 Curiestraße 2, D ...

IMPROVING SPEED AND ROBUSTNESS OF THE COMIS SOLVER

IMPROVING SPEED AND ROBUSTNESS OF THE COMIS SOLVER D.M. Lorenzettiand M.D. Sohn Indoor Environment Department Lawrence Berkeley National Laboratory Berkeley CA94720, USA Report LBNL-44792 Published in Proceedings of the 7 th International Conference on Air Distribution in Rooms (RoomVent 2000) v ...

Physician-Related Factors Involved in Patient Decisions to ...

Physician-Related Factors Involved in Patient Decisions to Enroll Onto Cancer Clinical Trials ByRobertL.Comis,MD,JonD.Miller,PhD,DianeD.Colaizzi,MA,andLindaG.Kimmel,PhD

A QUANTITATIVE SURVEY OF PUBLIC ATTITUDES TOWARDS CANCER ...

Robert L Comis, MD 1; Carolyn R Aldigé 2; Ellen L Stovall 3; Linda U Krebs, PhD, RN 4; Peter J Risher 5; and Humphrey J Taylor 5 1) Coalition of National Cancer Cooperative Groups, Philadelphia, PA; 2) Cancer Research Foundation of America, Alexandria, VA; 3) Cancer Leadership Council, Washington, DC ...

96-BBI-R1086 FINAL REPORT ANNEX 23. MULTI ZONE VENTILATION ...

Samenvatting (Dutch) Dit rapport is een overzicht van voorbeelden voor COMIS, binnen het kader van ANNEX 23, Multi zone Air Flow Models. Het is een afsluiting van het