Sputtr.com | Alternative Search Engine

Flared

SECTION 732 FLARED END SECTIONS

SECTION 732 FLARED END SECTIONS 732.1 Description. This work shall consist of furnishing and installing precast concrete or metal flared end sections of the size and shape shown on the plans. 732.1.1 Precast concrete flared end sections shall be used with concrete or vitrified clay culvert pipe ...

FLARED END SECTION

Drawing Number Date: Checked Drawn Drawing Name Approved: City Engineer L:\ENGINEERING AND BUILDING\ENGINEERING\DETAILS AND STANDARDS\ ILLINOIS C L RYSTAL AKE Engineering Division UD-02d UD-02d 3 1 1.

SECTION 1036 -- METAL FLARED-END SECTIONS

- 693 - SECTION 1036 -- METAL FLARED-END SECTIONS 1036.01 -- Description Flared-end sections for corrugated metal pipe shall be zinc-coated (galvanized) steel or aluminum-coated steel. 1036.02 -- Material Characteristics 1.

SECTION 1037 -- REINFORCED CONCRETE PIPE, MANHOLE RISERS, AND ...

- 757 - SECTION 1037 -- REINFORCED CONCRETE PIPE, MANHOLE RISERS, AND FLARED-END SECTIONS 1037.01 -- Description This Specification provides NDR criteria for reinforced concrete pipe (round, elliptical, pipe-arch), reinforced concrete manhole risers, and concrete flared-end sections. 1037.02 ...

SECTION 725 -- BAR GRATES FOR FLARED-END SECTIONS

- 534 - SECTION 725 -- BAR GRATES FOR FLARED-END SECTIONS 725.01 -- Description This work shall consist of furnishing, installing, and painting/galvanizing bar grates on concrete or metal flared-end sections at the locations shown in the plans. 725.02 -- Material Requirements 1.

Flared End Sections

Springfield Plastics, Inc. Auburn, IL 62615 1-800-252-3361 1-800-451-TILE http://www.spipipe.com Flared End Sections Flared end sections on culvert pipe are necessary whenever there is concern about ditch erosion and scouring caused by high outflows from culverts.

Flared phacoemulsification tips to decrease ultrasound time ...

Flared phacoemulsification tips to decrease ultrasound time and energy in cataract surgery James I. McNeill, MD ABSTRACT Purpose: To determine the effect on ultrasound (US) time and energy of using flared phacoemulsificat ion tips in cataract surgery.

BDC07D-01 Standard Details

FLARED GUIDE RAIL TERMINAL AND TANGENT TERMINAL BDC07D-01 Standard Details

HANCOR HI-Q® FLARED END SECTION SPECIFICATIONS

Microsoft Word - DH1- Specifications.doc. Hancor, Inc. Drainage Handbook Specifications ♦ 1-25 _____ © Hancor, Inc., May, 2005 HANCOR HI-Q ® FLARED END SECTION SPECIFICATIONS Scope This specification describes 10 ...

SKEW BRIDGES @ ABUTMENT WITH FLARED WINGWALL)

bd-jtset1_eng bd-jtset1_eng. revised state of new york department of transportation office of structures deputy chief engineer (structures) approved: armorless bridge joint systems typical plans i bd-jt2e c of joint 3" joint opening joint seal elastomeric concrete header (typ.)