My backflow preventer sometimes leaks water from a relief valve. Can I remove or plug the valve to prevent water loss? The relief valve is installed to prevent water pressure from building up too high when the water in a water heater expands.

ASSE 1022 BACKFLOW PREVENT0R

Carbonated beverage dispensers without an approved internal air gap or vented backflow preventer for carbonated beverage dispensers and carbonated beverage dispensing systems shall have the water supply protected with a vented backflow preventer for carbonated beverage dispensers."

STOP BACKFLOW NEWS!

Double Check Valve Backflow Preventer Series 007 Sizes: 1/2" - 3" Series 709 Sizes: 2 1 / 2" - 10" No. 7 Sizes: 3 / 8" - 1" ☛ ☛ Dual Check Backflow Preventer

Under sizing Backflow Preventers

In the Fall 2004 issue of Cross Talk , the issue of oversized backflow preventers was discussed. It was determined that placing a backflow preventer on a water line of a size smaller than the backflow preventer would not be detrimental to the operation of the assembly.

ITEM 615.6089 39 - UNDERGROUND BACKFLOW PREVENTER AND WATER ...

ITEM 615.6089 39 - UNDERGROUND BACKFLOW PREVENTER AND WATER METER CONCRETE VAULT Page 1 of 4 7/09/2008 DESCRIPTION This work shall consist of furnishing and installing the underground backflow preventer and water meter concrete vault in accordance with the contract documents and as directed by ...

Testing Procedures for Backflow Preventers

Reduced Pressure Principle Backflow Preventer (Figure 39) Field testing of a reduced pressure principle backflow preventer is accomplished utilizing a differential pressure gauge.

Installation Criteria

Installation Criteria by Jim Purzycki, Orange County Director ABPA Southern California Chapter When installing a backflow preventer, there are many details that must be evaluated before you break out the wrenches.

Wilkins Backflow Prevention Device Owner's Manual

Before installing a Model 375 Backflow Preventer, flush the line thoroughly to remove all debris, chips and other foreign matter. If required, a strainer should be placed upstream of the Backflow Preventer.

CHARLOTTE-MECKLENBURG UTILITIES BACKFLOW PREVENTION BULLETIN

CHARLOTTE-MECKLENBURG UTILITIES BACKFLOW PREVENTION BULLETIN SUBJECT: Approval Procedures for CMUD-Required DATE: March 9, 1999 Backflow Preventer Installations PRIOR TO INSTALLING A CMUD-REQUIRED BACKFLOW PREVENTER, THE DESIGNER AND/OR INSTALLER MUST OBTAIN CMUD APPROVAL OF THE INSTALLATION ...

Backflow Preventer Installation Applications*