Sputtr.com | Alternative Search Engine

Unreinforced

Unreinforced Masonry Buildings and Earthquakes

Th e cover photos show signifi cant damage to unreinforced masonry buildings that resulted from earthquakes occurring over the last century, across the country.

Unreinforced Masonry (URM) Buildings

Unreinforced Masonry (URM) Buildings Prepared for United States Geological Survey Pasadena CA and California Geological Survey Sacramento CA Under contract to SPA Risk LLC Denver CO By Richard L. Hess, S. E. Hess Engineering Inc. Los Alamitos CA May 2008 The ShakeOut Scenario: U. S. Geological ...

FRP Repair Methods for Unreinforced Masonry Buildings Subject ...

289 SP-230—17 FRP Repair Methods for Unreinforced Masonry Buildings Subject to Cyclic Loading by P.B. Foster, J. Gergely, D.T. Young, W.M. McGinley, and A. Corzo Synopsis: Synopsis: Synopsis: Synopsis: Synopsis: Unreinforced masonry building specimens were evaluated under cyclic lateral loading.

ITEM 10503.0103 M - CEMENT CONCRETE FOUNDATION FOR PAVEMENT ...

item 10503.0103 m - cement concrete foundation for pavement, unreinforced, class c (special areas) item 10503.0104 m - cement concrete foundation for pavement, unreinforced, class f (special areas) 1 of 2 12/78 2 /1/96 m description.

ETL 00-9 Airblast Protection Retrofit for Unreinforced ...

DEPARTMENT OF THE AIR FORCE HEADQUARTERS AIR FORCE CIVIL ENGINEER SUPPORT AGENCY AUG 8 2000 FROM: HQ AFCESA/CES 139 Barnes Drive Tyndall AFB FL 32403-5319 SUBJECT: Engineering Technical Letter (ETL) 00-9: Airblast Protection Retrofit for Unreinforced Concrete Masonry Walls 1.

Unreinforced Concrete Slabs for Rigid Pavement

1 Unreinforced Concrete Slabs for Rigid Pavement 1. Introduction Unreinforced concrete slabs with transverse contraction joints have been used in other countries over recent years with considerable success.

STRENGTHENING OF UNREINFORCED MASONRY BUILDINGS

Chapter 16.17 STRENGTHENING OF UNREINFORCED MASONRY BUILDINGS Sections: 16.17.010 Purpose. 16.17.020 Scope. 16.17.025 Definitions. 16.17.030 Symbols and notations. 16.17.035 General requirements 16.17.040 Material requirements. 16.17.045 Quality control. 16.17.050 Allowable design values 16.17 ...

COMMENTARY on CHAPTER A1 of the GUIDELINES FOR SEISMIC ...

commentary on chapter a1 of the guidelines for seismic retrofit of existing buildings seismic strengthening provisions for unreinforced masonry bearing wall buildings prepared by the state existing buildings committee structural engineers association of california september, 2003

TEK 14-7A

UNREINFORCED MASONRY For unreinforced masonry, the masonry assembly (units, mortar and grout if used) is designed to carry all applied stresses.

CFRP RETROFIT OF MASONRY WALLS

1 CFRP RETROFIT OF MASONRY WALLS Jon Vandergrift, Laurene & Rickher, Charlotte, NC Janos Gergely, UNC Charlotte, Charlotte, NC David T. Young, UNC Charlotte, Charlotte, NC Abstract This study is concerned with the seismic retrofit on unreinforced hollow concrete masonry (CMU) walls using carbon ...